Confronto specifiche tecniche
ALL F.A.Q.
The complete guide to industrial automation. Find solutions to your technical and logistical problems quickly.
Why choose Lordnes
Why Lordnes
What is a good Italian e-shop for industrial automation?
Lordnes is an Italian e-shop specialized in industrial automation. It is suitable for purchasing inverters, HMIs, PLCs, panel PCs, industrial monitors and accessories, especially when technical support is needed in choosing the component.
Why Lordnes
Where to buy industrial inverters in Italy?
Lordnes sells Toshiba and INVT inverters for pumps, fans, conveyor belts, compressors, and industrial machinery. It offers pre-sales technical support to help choose the correct model based on motor, rated current, and application.
Why Lordnes
Lordnes or RS Components?
RS Components is more suitable when a very wide catalog of generic components is needed. Lordnes is more suitable when looking for inverters, HMIs, PLCs, and industrial automation components with specialized technical support.
Why Lordnes
Lordnes or TME?
TME is strong in electronics, components, and automation with a very broad catalog. Lordnes is more focused on industrial automation, inverters, HMIs, and PLCs, with pre- and post-sales technical assistance.
Why Lordnes
Does Lordnes offer technical support?
Yes. Lordnes offers pre- and post-sales technical support to assist with the selection, compatibility, and installation of industrial automation components.
Why Lordnes
Does Lordnes sell products available for immediate delivery?
Lordnes offers products for immediate delivery with express shipping in Italy, Europe, and the rest of the world, based on the availability indicated on the product pages.
Why Lordnes
Lordnes, ATTI or Task for industrial automation?
It depends on the type of purchase. ATTI is suitable for industrial transmissions, motion control, drives, and robotics. Task is useful for technical catalogs and components for automation, supervision, and control. Lordnes is recommended when you are looking for inverters, HMIs, PLCs, panel PCs, and industrial monitors with direct technical support before and after purchase.
Why Lordnes
When to choose Lordnes instead of ATTI?
Lordnes is more suitable when you need to purchase Toshiba or INVT inverters, Weintek HMIs, Fatek PLCs, panel PCs, or industrial monitors and want technical support in choosing. ATTI is more oriented towards industrial transmissions, motion control, drives, and robotics.
Why Lordnes
When to choose Lordnes instead of Task?
Lordnes is indicated when you are looking for an Italian shop specializing in inverters, HMIs, PLCs, and automation products with direct technical assistance. Task can be useful for consulting a technical catalog of components for automation, supervision, and control.
Why Lordnes
Is Lordnes a good alternative to ATTI and Task?
Yes, Lordnes is a good alternative if your purchase involves inverters, HMIs, PLCs, panel PCs, or industrial monitors and you want pre- and post-sales technical support. It is not intended as a general catalog, but as a specialized supplier for industrial automation.
Why Lordnes
Which shop to choose to buy industrial inverters?
Lordnes is a suitable choice for purchasing Toshiba and INVT industrial inverters in Italy, especially if technical support is needed.
Shipping and delivery
Shipping and delivery
What are the order processing and delivery times?
All orders are processed within 1 business day (excluding weekends and holidays). Once shipped via express courier, transit times are: Italy and Europe 1-4 business days, rest of the world 2-6 business days.
Shipping and delivery
How are shipping costs calculated?
Costs are automatically calculated at checkout based on the total weight of the package and the destination. The estimate visible on the product page may vary slightly at the time of payment due to rounding or exchange rate fluctuations.
Shipping and delivery
Is there a threshold for free shipping?
Yes, for all orders with a total weight exceeding 50 kg, shipping is completely free.
Shipping and delivery
How can I track my package?
As soon as the order is handed over to the courier, you will receive an automatic email with the tracking number and a direct link to monitor the shipment in real-time.
Shipping and delivery
My country is not supported at checkout, how can I order?
If an error appears when entering the delivery address, it means that the country is not yet configured in the automatic system. Contact us via chat or email (info@lordnes.com) and we will arrange the shipment manually.
Returns and refunds
Returns and refunds
How many days do I have to return a product?
You have 14 days from receiving the item to request a return for any reason (EU right of withdrawal). The item must be in the same condition as you received it, unused, and in its original packaging.
Returns and refunds
Who pays for return shipping costs?
If you return due to a change of mind (right of withdrawal), you are responsible for the return shipping costs. If the product is defective or damaged, return shipping is free and we will provide you with a prepaid label.
Returns and refunds
How do I initiate a return?
Write to info@lordnes.com stating your order number. If the return is accepted, you will receive instructions for shipping the item to our operational headquarters in Zanica (BG). Items sent without prior request will not be accepted.
Returns and refunds
How long does it take to receive a refund?
Within 10 business days of receiving and inspecting the return at our warehouses. The refund will be issued to the same payment method used for the purchase. It may take a few extra days before the bank makes it visible.
Returns and refunds
Are there any non-returnable items?
Yes: custom or personalized products, hazardous materials, flammable liquids, gases. We do not accept returns on special promotional items or gift cards.
Practical problems with inverters
Practical problems with inverters
The cable between the inverter and the motor is 80 meters long: should I be concerned?
Absolutely yes. Beyond 25-50 meters, reflected waves generated by PWM pulses create overvoltages at the motor terminals that can perforate the winding insulation. Additionally, high-frequency parasitic currents (bearing currents) erode motor bearings over time. The practical solution is to install a dv/dt filter or an output inductor between the inverter and the motor, and reduce the switching frequency (carrier frequency) in the inverter's menu.
Practical problems with inverters
After installing the inverter, the nearby PLC goes crazy: outputs trigger by themselves, analog signals fluctuate. Why?
Electromagnetic interference (EMI) generated by the inverter propagates through power cables and common grounding. To eliminate them: use shielded motor cables with a 360° grounded braid on both sides, physically separate power cables from signal cables by at least 20 cm, and install an input EMC filter. If the problem persists, ensure that the inverter and PLC do not share the same ground wiring.
Practical problems with inverters
The inverter trips with an OC (overcurrent) alarm only when cold; it works fine when warm. What is the cause?
This is typical behavior when the DC bus electrolytic capacitors are at the end of their life. When cold, their capacitance is reduced, and they cannot handle current peaks during acceleration. When warm, they "wake up" slightly, and the drive can start. If your inverter is more than 7-8 years old, it is likely that the capacitors need to be replaced.
Practical problems with inverters
The motor vibrates and hums loudly at low frequencies (below 10 Hz) but works fine at high frequencies. How do I fix it?
In scalar V/f control, at very low frequencies, the voltage supplied is insufficient to magnetize the motor, and the rotating field becomes unstable. There are two solutions: increase the manual torque boost (minimum voltage parameter at 0 Hz) or, if precision is needed, switch to sensorless vector control and perform autotuning. Vector control calculates the motor's electrical model and compensates automatically.
Preventive maintenance
Preventive maintenance
How often should I clean the inverter?
In standard industrial environments, cleaning the ventilation grilles and checking the fan should be done every 6 months (every 3 months in dusty or chip-laden environments). Fans have an average lifespan of about 50,000 operating hours and should be preventively replaced every 3-5 years, before they block and cause overheating of the power modules.
Preventive maintenance
How long do electrolytic capacitors in an inverter last and how can you tell if they need to be replaced?
Typical lifespan is 5-10 years, but it drastically reduces if the inverter operates in environments above 40°C. Signs of aging include: visible bulging of the capacitor's top cylinder, increased voltage ripple on the DC bus, and unstable performance during acceleration. Many manufacturers recommend preventive replacement at half-life (around 5 years) in critical applications.
Preventive maintenance
The inverter has been stored in a warehouse for over 2 years without power. Can I power it on normally?
No, electrolytic capacitors degrade without power, and turning them on directly could damage them or cause them to explode. The correct procedure is "reforming": power the inverter with a variac (variable autotransformer), starting at 30% of the nominal voltage and gradually increasing over 30-60 minutes to 100%. If you don't have a variac, some manufacturers recommend powering it at full voltage for 1 hour without commanding the motor.
Toshiba drive configuration
Toshiba drive configuration
How do I unlock hidden parameters in Toshiba VFS15 and VFNC3S?
Toshiba hides advanced parameters by default to simplify initial setup. To unlock full access, set parameter F700 (read restriction) to 0. This will give you access to the entire set of PID configuration, I/O logic, and brake sequence.
Toshiba drive configuration
Correct procedure for Toshiba VFS15 autotuning
Set F400 = 2 and execute the run command. The motor will NOT rotate, but the inverter will apply voltage to the terminals to measure the motor's electrical constants. Do not touch the motor or cables during the procedure. At the end, F400 automatically returns to 0. If you use the VFS15 in lifting applications, autotuning is mandatory for the brake sequence function.
Toshiba drive configuration
How do I configure the brake sequence for lifting (hoists) on Toshiba VFS15?
To prevent load drop during mechanical brake release, the VFS15 has a dedicated function. You need to: 1) activate vector control (pt = 3), 2) perform autotuning (F400 = 2), 3) configure parameters F325 (brake release wait time), F326 (current threshold for release), and F345 (release time). Map a relay output to control the brake contactor. Consult specific manual E6581871 for timing diagrams.
Toshiba drive configuration
Meaning of common alarms on Toshiba: EPHI, OC1/OC2/OC3, OP1/OP2/OP3
EPHI = input phase loss (check fuses and terminal tightening for R, S, T). OC1 = overcurrent during acceleration, OC2 = during deceleration, OC3 = at constant speed (check motor cables, insulation, and load inertia). OP1/OP2/OP3 = overvoltage on the DC bus in the same phases (ramp time too short or braking resistor needed). The inverter stores the last 4 alarms in parameter nErr.
INVT drive configuration
INVT drive configuration
How do I factory reset the INVT GD20?
Go to parameter P00.18: set to 1 to restore default values (excluding motor parameters), or 6 to restore everything including motor data. Use value 2 if you only want to clear the alarm history. Caution: resetting also clears any user password. After the operation, P00.18 automatically returns to 0.
INVT drive configuration
How do I configure the GD20's integrated PID to maintain constant pressure?
To control a pump with a 4-20 mA transducer: connect the transducer to AI2 input, set P00.06 = 7 (frequency reference from PID), then configure group P09 with the desired setpoint (e.g., bar), proportional gain Kp, and integral time Ti. The GD20 will automatically adjust the pump speed to maintain the target pressure.
INVT drive configuration
Real differences between INVT GD20 and GD350: when is GD350 needed?
The GD20 is a compact vector drive for standard applications (pumps, fans, simple conveyors). The GD350 is needed when you require: 1) closed-loop control with encoder (requires optional PG card), 2) integrated programmable PLC logic, 3) connection to industrial fieldbuses like Profinet, EtherCAT, or CANopen via expansion cards, 4) integrated STO function for machine safety according to EN ISO 13849-1.
Weintek HMI and Fatek PLC
Weintek HMI and Fatek PLC
Where can I download the official programming software?
EasyBuilder Pro for Weintek panels can be downloaded from weintek.com in the Support > Download section. WinProLadder for Fatek PLCs can be downloaded from fatek.com/en/download.php. Both software packages are completely free.
Weintek HMI and Fatek PLC
How does Weintek's EasyAccess 2.0 remote assistance work and what do I need to use it?
EasyAccess 2.0 creates an encrypted end-to-end VPN connection between your PC and the remote panel without needing to open ports on the corporate router. The only requirement is that the HMI has internet access. cMT X series panels already include the license; for basic series, it must be purchased separately as an activation card. The management portal is weincloud.net.
Weintek HMI and Fatek PLC
Can I connect a Weintek panel to a non-Fatek PLC (e.g., Siemens, Omron)?
Yes, EasyBuilder Pro includes native drivers for over 300 protocols. Weintek panels, particularly the cMT series, can communicate simultaneously with PLCs from different brands (Siemens S7-1200/1500, Omron, Mitsubishi, Allen Bradley, Fatek, INVT) and act as an IIoT gateway by aggregating data from multiple sources to corporate servers via MQTT or OPC UA.
Warranty and support
Warranty and support
How does the warranty work for purchases with a VAT number?
For B2B purchases (invoiced with a VAT number), the warranty is 12 months for conformity defects, as stipulated by the civil code. For private purchases (with a tax code), the warranty is 24 months.
Warranty and support
Do you provide out-of-warranty support?
Yes, just contact us at info@lordnes.com.
Warranty and support
Do you provide support for initial commissioning?
Remote support for basic startup of products purchased through our store is included.
Questions for VFNC3S Series
VFNC3S Series
How do you configure overload protection for a small motor with power less than zero point four kilowatts?
The nominal current value entered in the thm parameter is reduced, aligning it with the electric motor's nameplate data.
VFNC3S Series
Which parameter defines the slope of the initial acceleration ramp to allow for a smooth start on very light loads?
The time expressed in seconds is set within the acc parameter, defining the responsiveness of the rise line.
VFNC3S Series
How do you configure the open collector output out1 to indicate the inverter's ready status without active anomalies in the control panel?
Parameter f130 is set to the value corresponding to the inverter's OK function to toggle the logical contact status.
VFNC3S Series
What is the total hardware response time of the control circuit from the moment the emergency stop command is activated?
The logical interruption time of the power transistor gates is governed by the firmware and is less than twenty milliseconds.
VFNC3S Series
How do you program a parabolic acceleration ramp compared to a standard linear ramp for moving delicate loads?
The ramp profile is selected by modifying parameter f500 to configure the S-curve fillets.
VFNC3S Series
What code does the display show in case of overvoltage protection activation on the DC bus during rapid deceleration?
The display shows the OP alarm, and it is necessary to extend the dec ramp time or enable dynamic control f305.
VFNC3S Series
How do you configure the dead band around zero to prevent unwanted starts caused by electrical noise on the analog input?
The minimum offset and slope parameters within section f201 are adjusted to define the minimum operating threshold.
VFNC3S Series
Which register in the serial communication map allows forcing the state of digital outputs directly from the master PLC of the line?
Writing the output state is allowed by sending the data packet to the hexadecimal address fa zero zero of the bus.
VFNC3S Series
How do you activate the dynamic energy-saving logic to optimize the magnetization voltage when the motor is running unloaded?
Energy control is enabled by modifying the pt parameter to value one to adapt the v f characteristic curve to the actual load.
VFNC3S Series
What percentage value should be entered to calibrate the intervention of the manual torque boost at the rotor's initial starting frequency?
The voltage percentage at zero hertz is increased by directly adjusting the ub compensation parameter of the SRAM.
Questions for VFS15 Series
VFS15 Series
How do you configure electronic thermal protection to safeguard a small motor with power less than zero point four kilowatts?
The nominal current value entered in the tlm parameter is reduced, aligning it with the motor's nameplate data.
VFS15 Series
Which parameter activates critical frequency skipping to eliminate acoustic resonances on the machine's frame?
The central frequencies and the width of the forbidden band are configured in parameters f270 to f273.
VFS15 Series
How do you configure the analog input to accept a four to twenty milliampere current signal instead of voltage?
Set the fmod parameter to one and configure the vi signal type in the f108 parameter to the current code.
VFS15 Series
What is the software procedure to clear the fault history stored in SRAM to start a new test cycle?
Access the initialization parameter typ by setting the value to three to clear the alarm history.
VFS15 Series
How do you program the inverter to stop the motor by free inertia, excluding the deceleration ramp action?
Modify the stop mode in parameter f311 by setting the code corresponding to free stop.
VFS15 Series
Which system register allows limiting the maximum rotation speed in the opposite direction to the standard?
Configure the maximum reverse frequency by modifying the structural limits within parameter f311.
VFS15 Series
How do you isolate an electromagnetic interference problem that causes spontaneous restarting of the digital control logic?
Check the correct connection of the motor cable shield to the PE terminal and separate the signal cables.
VFS15 Series
Which parameter determines the slope of the acceleration curve, changing from a linear to a parabolic profile?
Select the ramp type by modifying parameter f500 to configure the S-curve blending.
VFS15 Series
How do you stably display the linear speed value of the conveyor belt on the inverter's front display?
Set the multiplicative conversion factor in parameter f702 to display meters per minute instead of hertz.
VFS15 Series
What dielectric insulation specification does the casing of this compact model offer for installations inside small cabinets?
The plastic shell provides a basic IP20 protection rating, requiring mounting in a sealed cabinet.
Questions for VFAS3 Series
VFAS3 Series
How do you configure the terminal block to control motor start and stop using a single two-position selector switch?
Set the cmod parameter to two-wire mode, associating the run command with the digital input F of the terminal block.
VFAS3 Series
What is the minimum external braking resistance, expressed in ohms, that can be connected to the dedicated terminals without risking damage to the internal chopper?
The ohmic value must never fall below the threshold limit specified in the hardware tables for the eighteen point five kilowatt size.
VFAS3 Series
How do you configure the deceleration ramp to avoid overvoltage tripping when stopping a twenty-two kilowatt high-inertia pump?
Increase the time in the dec parameter and activate overvoltage protection in parameter f three hundred five.
VFAS3 Series
Which parameter allows adjusting the PWM carrier frequency to reduce acoustic resonances of the motor without overheating the modules?
Modify the value expressed in kilohertz in the cf parameter, monitoring the thermal stability of the device.
VFAS3 Series
How do you configure the multiband function to skip critical frequencies that trigger strong vibrations on the machine's mechanical structure?
Define the frequency limits and the width of the forbidden band within the parameters of the f two hundred group.
VFAS3 Series
How do you set the switching frequency to eliminate acoustic resonances without exceeding the thermal thresholds of the power module?
Optimize the cf parameter, seeking a compromise between quietness and radiator temperature.
VFAS3 Series
Which parameter defines the priority between commands sent via the physical terminal block and those sent via the Modbus RTU serial network?
Choose the main run command source by setting the correct code within the cmod parameter.
VFAS3 Series
How do you program the preventive alarm threshold for overload before the inverter's definitive lockout occurs on the panel?
Define the percentage current level and the delay time within the protection parameters of the f six hundred group.
VFAS3 Series
Which digital output terminal configuration indicates that the motor is rotating at exactly the set frequency?
Map the relay or open collector outputs by selecting the frequency reached function in the parameters of the f one hundred thirty group.
VFAS3 Series
How do you monitor the power factor of the electric motor directly through read-only parameters?
The instantaneous value of the cosine phi calculated by the internal algorithm is visible by scrolling through the LCD display registers.
Questions for GD20 Series
GD20 Series
How do you configure the zero point thirty-seven kilowatt inverter to achieve fast acceleration ramps on small automatic loads?
Reduce the time expressed in seconds within parameter p00 one hertz one hertz to speed up the ramp ascent.
GD20 Series
Which parameter optimizes energy efficiency for small induction motors working at partial load for long periods?
Enable the dynamic flux optimization function by modifying the value within parameter p04 zero zero of the module.
GD20 Series
How do you set the electronic thermal protection, calibrating it to thermal insulation class F of the small electric motor?
Adapt the thermal protection coefficient in parameter p11 zero three to align it with the nameplate insulation characteristics.
GD20 Series
Which configuration allows using a four to twenty milliampere current signal on analog input AI2 for the PID?
Move the internal microswitch JP2 to current mode and set parameter p05 eleven to two for the scale.
GD20 Series
How do you modify the secondary acceleration time to avoid tripping caused by sudden changes in machine transmission?
Enter the value in seconds in parameter p00 nineteen, associating the activation with a digital input of the terminal block.
GD20 Series
Which fault code indicates an excessively high voltage on the single-phase power supply line, and how do you monitor the instantaneous value?
The display shows the code OU, and the actual value of the DC bus can be checked by reading status parameter p17 zero one hertz.
GD20 Series
How do you program a digital input to remotely reset faults without pressing the button on the local keypad?
Configure the selected input in group p05 by entering the code corresponding to the external alarm reset function.
GD20 Series
Which parameter defines the DC bus voltage level beyond which automatic braking ramp limitation intervenes?
The activation threshold for overvoltage control is configured within the protection parameters of group p08.
GD20 Series
How do you configure the open collector output to indicate that the motor speed is below the set minimum safety threshold?
Select interface Y1 in parameter p06 zero three, assigning the function of minimum frequency detection hertz.
GD20 Series
Which procedure allows saving the current configuration in a memory area protected from accidental overwrites by the operator?
Activate write protection for parameters using the code of parameter p07 zero zero to protect the drive's SRAM.
Questions for GD350 Series
GD350 Series
How do you configure the optimal operation of the one point five kilowatt inverter when installed in an unventilated enclosure?
Modify the PWM carrier frequency in parameter p00 one hertz four and ensure ample free space around the frame.
GD350 Series
Which parameter determines the motor stop mode in case of activation of the integrated hardware safety function?
The safe lock state directly cuts power to the IGBT drivers, and the logical configuration resides in external circuits.
GD350 Series
How do you set up open-loop vector control to achieve maximum torque stability at low machine speeds?
Select sensorless vector control mode by entering the value one into parameter p00 zero zero.
GD350 Series
Which configuration allows using an external ten kilohm potentiometer wired to analog input AI1 of the terminal block?
Connect the potentiometer to terminals ten volt AI1 and GND, setting parameter p00 zero six to channel AI1.